MolGraph
CompoundsDocumentationComplianceAbout
MolGraph

Research chemical sourcing and molecular building block RFQ workflows.

MolGraph is operated by Tessorix Inc.

support@molgraph.com

Products are intended for laboratory research use only and are not for human or veterinary use.

Compounds

  • Compound catalog
  • In-stock with prices
  • Research applications
  • Catalog data snapshot
  • Patent compound sourcing
  • Request Quote

Categories

  • Protected amines
  • Boronic acids
  • Fluorinated building blocks
  • Heterocycles
  • Pharmaceutical intermediates
  • Custom synthesis

Company

  • About
  • Contact

Documentation

  • Quality Documentation
  • SDS Disclaimer

Compliance

  • Compliance

Legal

  • Returns & Refunds
  • Terms
  • Privacy

Copyright © 2026 MolGraph. All Rights Reserved.

Home/Compounds/CAS 1000577-80-9/Safety Reference
CAS 1000577-80-9Preliminary Safety ReferenceNot a supplier-issued SDSSupplier SDS by request

CAS 1000577-80-9 Safety Reference and Supplier SDS Request

4-Bromo-2,5-difluorophenyl isothiocyanate

Back to CAS detail

Preliminary reference disclaimer

This preliminary safety reference is generated from structured MolGraph catalog fields and public reference-style data. It is not a supplier-issued Safety Data Sheet and should not be used as a substitute for supplier-issued documentation, workplace safety review, transport classification, or regulatory compliance decisions. For supplier SDS or COA, submit a documentation request through MolGraph.

Documentation status

Preliminary safety reference

Available

Supplier-issued SDS

Available by request

COA

Available by RFQ / lot confirmation

Transport classification

Requires shipment review

Identity

CAS Number

1000577-80-9

Chemical name

4-Bromo-2,5-difluorophenyl isothiocyanate

Molecular formula

C7H2BrF2NS

Molecular weight

250.07 g/mol

Synonyms

1-bromo-2,5-difluoro-4-isothiocyanato-benzene

InChIKey

DZCHDQYIMUERSQ-UHFFFAOYSA-N

PubChem CID

26599114

Hazard / GHS Reference

Signal word

Danger

Catalog reference cue; confirm supplier documentation before use.

Hazard statements

H315, H317, H319, H330, H334, H335, H351, H412

Catalog reference cue; confirm supplier documentation before use.

Handling & PPE

  • Closed. Dry. Store in a well-ventilated area.
  • Use a P95 (US) or P1 (EU UK 143) particulate respirator if exposed to hazardous environments. For higher level of protection, use an OV/AG/P99 (US) or ABEK-P2 (EU UK 143) gas filter. Respirators and parts must be tested and approved by government standards such as NIOSH (US) or CEN (EU).
  • Dispose of the remaining and non-recyclable solution to a licensed company. Contact a professional institution with a waste disposal license to handle this substance. Dissolve or mix with flammable solvents, and incinerate contaminated packaging in a chemical incinerator with post-combustion and washing functions. Contaminated packaging is disposed of as unused product.

First Aid / Accidental Release

  • Do not give anything to an unconscious person. Rinse mouth with water. Consult a physician.
  • If inhaled, move the person to fresh air. If breathing stops, perform artificial respiration. Consult a physician.
  • Rinse with plenty of water for at least 15 minutes and consult a physician.
  • Wash with soap and plenty of water. Consult a physician.
  • Do not generate dust when collecting and disposing. Sweep and shovel up. Place in a suitable closed container for disposal.
  • Use personal protective equipment. Avoid dust generation. Avoid inhalation of vapors, mists or gases. Ensure adequate ventilation. Evacuate personnel to a safe area. Avoid inhalation of dust. See
  • Do not allow the product to enter drains.
  • Dispose of the remaining and non-recyclable solution to a licensed company. Contact a professional institution with a waste disposal license to handle this substance. Dissolve or mix with flammable solvents, and incinerate contaminated packaging in a chemical incinerator with post-combustion and washing functions. Contaminated packaging is disposed of as unused product.

Firefighting / Stability

  • Use self-contained breathing apparatus if necessary.
  • and reaction activity
  • carbon monoxide, carbon dioxide, hydrogen bromide, hydrogen fluoride, nitrogen oxides, sulfur oxides

Physical and Chemical Reference

XLogP

4.2

Catalog reference value; verify against supplier SDS before use.

Transport / Shipment Review

Shipment review

Shipment details require review before fulfillment.

Transport classification must be confirmed using supplier SDS and shipment documentation before dispatch.

  • Transport classification must be confirmed using supplier SDS and shipment documentation before dispatch.

Need supplier documentation?

Request through MolGraph:

  • Supplier-issued SDS
  • COA
  • Purity and pack size confirmation
  • Availability and lead time review
  • Shipment documentation review

Catalog-Specific Reference Cues

  • 4-Bromo-2,5-difluorophenyl isothiocyanate (CAS 1000577-80-9) is an English MolGraph catalog reference, molecular formula C7H2BrF2NS and molecular weight 250.07 g/mol.
  • 4-Bromo-2,5-difluorophenyl isothiocyanate is listed for synthetic chemistry workflows, heterocyclic building-block research, research chemical sourcing. MolGraph records supplier catalog evidence for this CAS, with RFQ and documentation request workflows available. Identity fields are backed by local PubChem/structure normalization where available.
  • Use this page to review identity data, application tags, sourcing readiness, and RFQ context for heterocyclic building-block research, synthetic chemistry workflows, research chemical sourcing.

Related catalog entries

Related public CAS links are not available for this reference page.

MolGraph Preliminary Safety Reference - Not a supplier-issued SDS. This preliminary safety reference is generated from structured MolGraph catalog fields and public reference-style data. It is not a supplier-issued Safety Data Sheet and should not be used as a substitute for supplier-issued documentation, workplace safety review, transport classification, or regulatory compliance decisions. For supplier SDS or COA, submit a documentation request through MolGraph.