MolGraph
CompoundsDocumentationComplianceAbout
MolGraph

Research chemical sourcing and molecular building block RFQ workflows.

MolGraph is operated by Tessorix Inc.

support@molgraph.com

Products are intended for laboratory research use only and are not for human or veterinary use.

Compounds

  • Compound catalog
  • In-stock with prices
  • Research applications
  • Catalog data snapshot
  • Patent compound sourcing
  • Request Quote

Categories

  • Protected amines
  • Boronic acids
  • Fluorinated building blocks
  • Heterocycles
  • Pharmaceutical intermediates
  • Custom synthesis

Company

  • About
  • Contact

Documentation

  • Quality Documentation
  • SDS Disclaimer

Compliance

  • Compliance

Legal

  • Returns & Refunds
  • Terms
  • Privacy

Copyright © 2026 MolGraph. All Rights Reserved.

Home/Compounds/CAS 108481-92-1/Safety Reference
CAS 108481-92-1Preliminary Safety ReferenceNot a supplier-issued SDSSupplier SDS by request

CAS 108481-92-1 Safety Reference and Supplier SDS Request

4-(4-Isopropyl-phenyl)-thiazol-2-ylamine

Back to CAS detail

Preliminary reference disclaimer

This preliminary safety reference is generated from structured MolGraph catalog fields and public reference-style data. It is not a supplier-issued Safety Data Sheet and should not be used as a substitute for supplier-issued documentation, workplace safety review, transport classification, or regulatory compliance decisions. For supplier SDS or COA, submit a documentation request through MolGraph.

Documentation status

Preliminary safety reference

Available

Supplier-issued SDS

Available by request

COA

Available by RFQ / lot confirmation

Transport classification

Requires shipment review

Identity

CAS Number

108481-92-1

Chemical name

4-(4-Isopropyl-phenyl)-thiazol-2-ylamine

Molecular formula

C12H14N2S

Molecular weight

218.32 g/mol

Synonyms

2-amino-4-(4-isopropylphenyl)thiazole; 4-(4-isopropylphenyl)thiazol-2-amine; 4-(4-isopropylphenyl)-1,3-thiazol-2-amine; 4-[4-(propan-2-yl)phenyl]-1,3-thiazol-2-amine; 2-Amino-4-(4-isopropylphenyl)- thiazole; 4-(4-Isopropylphenyl)thiazol-2-ylamine; 2-Thiazolamine,4-[4-(1-methylethyl)phenyl]-; 2-Thiazolamine, 4-[4-(1-methylethyl)phenyl]-; Cambridge id 5751226; Oprea1_178190; Oprea1_717317; 2-amino-4-(4-isopropylphenyl)-thiazole

InChIKey

UFBAQAAATDLTAZ-UHFFFAOYSA-N

PubChem CID

673693

Hazard / GHS Reference

No GHS reference data is available in the current MolGraph catalog record.

Handling & PPE

  • Closed. Dry. Store in a well-ventilated area. Recommended storage conditions: Lightproof, purged, room temperature
  • Use a P95 (US) or P1 (EU UK 143) particulate respirator if exposed to hazardous environments. For higher level of protection, use an OV/AG/P99 (US) or ABEK-P2 (EU UK 143) gas filter. Respirators and parts must be tested and approved by government standards such as NIOSH (US) or CEN (EU).
  • The remaining and non-recyclable solution should be handed over to a licensed company for disposal. Contact a professional institution with a waste disposal license to handle this substance. Combust the contaminated packaging in a chemical incinerator with combustion and washing functions. Contaminated packaging should be disposed of as unused product.

First Aid / Accidental Release

  • Do not give anything to an unconscious person. Rinse mouth with water. Consult a physician.
  • If inhaled, move the person to fresh air. If breathing stops, perform artificial respiration. Consult a physician.
  • Rinse with plenty of water for at least 15 minutes and consult a physician.
  • Wash with soap and plenty of water. Consult a physician.
  • Do not generate dust when collecting and disposing. Sweep and shovel up. Place in a suitable closed container for disposal.
  • Use personal protective equipment and emergency procedures. Avoid dust generation. Avoid inhalation of vapors, mists or gases. Ensure adequate ventilation. Evacuate personnel to a safe area. Avoid inhalation of dust. See
  • Do not allow the product to enter drains.
  • The remaining and non-recyclable solution should be handed over to a licensed company for disposal. Contact a professional institution with a waste disposal license to handle this substance. Combust the contaminated packaging in a chemical incinerator with combustion and washing functions. Contaminated packaging should be disposed of as unused product.

Firefighting / Stability

  • Wear a self-contained breathing apparatus for fire fighting operations if necessary.
  • and reaction activity
  • carbon monoxide, carbon dioxide, nitrogen oxides, sulfur oxides

Physical and Chemical Reference

Appearance

Solid

Catalog reference value; verify against supplier SDS before use.

Transport / Shipment Review

Shipment review

Shipment details require review before fulfillment.

Transport classification must be confirmed using supplier SDS and shipment documentation before dispatch.

  • Transport classification must be confirmed using supplier SDS and shipment documentation before dispatch.

Need supplier documentation?

Request through MolGraph:

  • Supplier-issued SDS
  • COA
  • Purity and pack size confirmation
  • Availability and lead time review
  • Shipment documentation review

Catalog-Specific Reference Cues

  • 4-(4-Isopropyl-phenyl)-thiazol-2-ylamine (CAS 108481-92-1) is maintained as a cataloged research chemical with formula C12H14N2S, molecular weight 218.32 g/mol, PubChem CID 673693.
  • Use this page for identity verification, package-aware sourcing review, and RFQ preparation; structure-derived tags include nitrogen-containing heterocycle, fragment-like structure profile, lead-like structure profile, drug-like rule profile.

Related catalog entries

Related public CAS links are not available for this reference page.

MolGraph Preliminary Safety Reference - Not a supplier-issued SDS. This preliminary safety reference is generated from structured MolGraph catalog fields and public reference-style data. It is not a supplier-issued Safety Data Sheet and should not be used as a substitute for supplier-issued documentation, workplace safety review, transport classification, or regulatory compliance decisions. For supplier SDS or COA, submit a documentation request through MolGraph.