MolGraph
ProductsChemical familiesDocumentationAbout
MolGraph

Research chemical sourcing and molecular building block RFQ workflows.

MolGraph is operated by Tessorix Inc.

support@molgraph.com

Products are intended for laboratory research use only and are not for human or veterinary use.

Compounds

  • Compound catalog
  • In-stock with prices
  • Chemical families & applications
  • Catalog data snapshot
  • Patent compound sourcing
  • Request Quote

Categories

  • Protected amines
  • Boronic acids
  • Fluorinated building blocks
  • Heterocycles
  • Pharmaceutical intermediates
  • Custom synthesis

Company

  • About
  • Contact

Documentation

  • Quality Documentation
  • SDS Disclaimer

Compliance

  • Compliance

Legal

  • Returns & Refunds
  • Terms
  • Privacy

Copyright © 2026 MolGraph. All Rights Reserved.

Home/Compounds/CAS 159414-97-8/Safety Reference
CAS 159414-97-8Preliminary Safety ReferenceNot a supplier-issued SDSSupplier SDS by request

CAS 159414-97-8 Safety Reference and Supplier SDS Request

N4-Acetyl-2'-fluoro-2'-deoxycytidine

Back to CAS detail

Preliminary reference disclaimer

This preliminary safety reference is generated from structured MolGraph catalog fields and public reference-style data. It is not a supplier-issued Safety Data Sheet and should not be used as a substitute for supplier-issued documentation, workplace safety review, transport classification, or regulatory compliance decisions. For supplier SDS or COA, submit a documentation request through MolGraph.

Documentation status

Preliminary safety reference

Available

Supplier-issued SDS

Available by request

COA

Available by RFQ / lot confirmation

Transport classification

Requires shipment review

Identity

CAS Number

159414-97-8

Chemical name

N4-Acetyl-2'-fluoro-2'-deoxycytidine

Molecular formula

C11H14FN3O5

Molecular weight

287.24 g/mol

Synonyms

Ac-2'-F-dC; N4-Acetyl-2'-deoxy-2'-fluorocytidine; N-(1-((2R,3R,4R,5R)-3-fluoro-4-hydroxy-5-(hydroxymethyl)tetrahydrofuran-2-yl)-2-oxo-1,2-dihydropyrimidin-4-yl)acetamide; N4-Acetyl-2/'-Fluoro-2/'-deoxycytidine; 2'-F-Ac-C; N-{1-[(2R,3R,4R,5R)-3-fluoro-4-hydroxy-5-(hydroxymethyl)oxolan-2-yl]-2-oxo-1,2-dihydropyrimidin-4-yl}acetamide; N-Acetyl-2'-deoxy-2'-fluorocytidine; 4-N-Acetyl-2'-fluoro-2'-deoxycytidine; N4-Acetyl-2 inverted exclamation mark -fluoro-2 inverted exclamation mark -deoxycytidine; N4-Acetyl-2 inverted exclamation marka-deoxy-2 inverted exclamation marka-fluorocytidine; N-[1-[(2R,3R,4R,5R)-3-fluoro-4-hydroxy-5-(hydroxymethyl)tetrahydrofuran-2-yl]-2-oxo-pyrimidin-4-yl]acetamide

InChIKey

NLXVKEFNBVLDLD-PEBGCTIMSA-N

PubChem CID

22094552

Hazard / GHS Reference

Signal word

Warning

Catalog reference cue; confirm supplier documentation before use.

Hazard statements

H302, H315, H319, H335

Catalog reference cue; confirm supplier documentation before use.

Handling & PPE

  • Including any incompatibility. Close tightly. Dry. Store in a well-ventilated area. Recommended storage conditions: keep away from light, inert gas, -20°C
  • Avoid contact with skin and eyes. Avoid generating dust and aerosols. Provide appropriate ventilation in areas where dust is generated. General fire protection measures.
  • If exposed to a harmful environment, use a P95 (US) or P1 (EU UK 143) particulate respirator. For higher level of protection, use an OV/AG/P99 (US) or ABEK-P2 (EU UK 143) gas filter. Respirators must be tested and approved by government standards such as NIOSH (US) or CEN (EU).
  • The remaining and non-recyclable solutions should be handed over to a licensed company for disposal. Contact a professional institution with a waste disposal license to handle this substance. Dissolve or mix with flammable solvents and burn in a chemical incinerator with post-combustion and washing functions. Contaminated packaging. Dispose of as unutilized product.

First Aid / Accidental Release

  • Do not give anything to an unconscious person. Rinse mouth with water. Consult a physician.
  • If inhaled, move the person to fresh air. If breathing stops, perform artificial respiration. Consult a physician.
  • Rinse with plenty of water for at least 15 minutes and consult a physician.
  • Wash with soap and plenty of water. Consult a physician.
  • Do not generate dust when collecting and disposing. Sweep and shovel up. Place in a suitable closed container for disposal.
  • Do not allow the product to enter drains.
  • The remaining and non-recyclable solutions should be handed over to a licensed company for disposal. Contact a professional institution with a waste disposal license to handle this substance. Dissolve or mix with flammable solvents and burn in a chemical incinerator with post-combustion and washing functions. Contaminated packaging. Dispose of as unutilized product.

Firefighting / Stability

  • If necessary, wear a self-contained breathing apparatus for firefighting.
  • Reactivity and stability
  • Carbon monoxide, carbon dioxide, hydrogen fluoride, nitrogen oxides

Physical and Chemical Reference

XLogP

-0.3

Catalog reference value; verify against supplier SDS before use.

Transport / Shipment Review

Shipment review

Shipment details require review before fulfillment.

Transport classification must be confirmed using supplier SDS and shipment documentation before dispatch.

  • Transport classification must be confirmed using supplier SDS and shipment documentation before dispatch.

Need supplier documentation?

Request through MolGraph:

  • Supplier-issued SDS
  • COA
  • Purity and pack size confirmation
  • Availability and lead time review
  • Shipment documentation review

Catalog-Specific Reference Cues

  • N4-Acetyl-2'-fluoro-2'-deoxycytidine (CAS 159414-97-8) is listed in the Advanced Chemicals portfolio, with molecular formula C11H14FN3O5 and molecular weight 287.24 g/mol.
  • Intended for research building-block and synthetic chemistry workflows; structure-derived tags include nitrogen-containing heterocycle.

Related catalog entries

Related public CAS links are not available for this reference page.

MolGraph Preliminary Safety Reference - Not a supplier-issued SDS. This preliminary safety reference is generated from structured MolGraph catalog fields and public reference-style data. It is not a supplier-issued Safety Data Sheet and should not be used as a substitute for supplier-issued documentation, workplace safety review, transport classification, or regulatory compliance decisions. For supplier SDS or COA, submit a documentation request through MolGraph.