MolGraph
CompoundsDocumentationComplianceAbout
MolGraph

Research chemical sourcing and molecular building block RFQ workflows.

MolGraph is operated by Tessorix Inc.

support@molgraph.com

Products are intended for laboratory research use only and are not for human or veterinary use.

Compounds

  • Compound catalog
  • In-stock with prices
  • Research applications
  • Catalog data snapshot
  • Patent compound sourcing
  • Request Quote

Categories

  • Protected amines
  • Boronic acids
  • Fluorinated building blocks
  • Heterocycles
  • Pharmaceutical intermediates
  • Custom synthesis

Company

  • About
  • Contact

Documentation

  • Quality Documentation
  • SDS Disclaimer

Compliance

  • Compliance

Legal

  • Returns & Refunds
  • Terms
  • Privacy

Copyright © 2026 MolGraph. All Rights Reserved.

Home/Compounds/CAS 162356-89-0/Safety Reference
CAS 162356-89-0Preliminary Safety ReferenceNot a supplier-issued SDSSupplier SDS by request

CAS 162356-89-0 Safety Reference and Supplier SDS Request

4-(tert-Butyldimethylsilyloxymethyl)phenylboronic acid

Back to CAS detail

Preliminary reference disclaimer

This preliminary safety reference is generated from structured MolGraph catalog fields and public reference-style data. It is not a supplier-issued Safety Data Sheet and should not be used as a substitute for supplier-issued documentation, workplace safety review, transport classification, or regulatory compliance decisions. For supplier SDS or COA, submit a documentation request through MolGraph.

Documentation status

Preliminary safety reference

Available

Supplier-issued SDS

Available by request

COA

Available by RFQ / lot confirmation

Transport classification

Requires shipment review

Identity

CAS Number

162356-89-0

Chemical name

4-(tert-Butyldimethylsilyloxymethyl)phenylboronic acid

Molecular formula

C13H23BO3Si

Molecular weight

266.22 g/mol

Synonyms

(4-(((tert-Butyldimethylsilyl)oxy)methyl)phenyl)boronic acid; 4-TBSMS-hydroxymethylphenylboronic acid; 4-TBDMS-HYDROXYMETHYLPHENYLBORONIC ACID; C13H23BO3Si; [4-[[[1,1-Dimethylethyl)dimethylsilyl]oxy]methyl]phenylboronic Acid; Boronic acid, B-[4-[[[(1,1-dimethylethyl)dimethylsilyl]oxy]methyl]phenyl]-; (4-{[(tert-butyldimethylsilyl)oxy]methyl}phenyl)boronic acid; 4-TBDMSO-METHYLPHENYLBORONIC ACID; 4-(t-Butyldimethylsiloxymethyl)phenylboronic acid; (4-(((tert-Butyldimethylsilyl)oxy)methyl)phenyl)boronicacid; [4-({[tert-Butyl(dimethyl)silyl]oxy}methyl)phenyl]boronic acid; [4-({[tert-Butyldi(methyl)silyl]oxy}methyl)phenyl]boronic acid

InChIKey

UMYBPELCCZPPOD-UHFFFAOYSA-N

PubChem CID

23365435

Hazard / GHS Reference

Signal word

Warning

Catalog reference cue; confirm supplier documentation before use.

Hazard statements

H302, H315, H319, H335

Catalog reference cue; confirm supplier documentation before use.

Handling & PPE

  • Keep container tightly closed and dry. Store in a well-ventilated place. Recommended storage conditions: nitrogen-purged, 2-8°C
  • Use a P95 (US) or P1 (EU UK 143) particulate respirator if exposed to harmful environments. For higher level of protection, use an OV/AG/P99 (US) or ABEK-P2 (EU UK 143) gas filter. Respirators must be tested and approved by government standards such as NIOSH (US) or CEN (EU).
  • Waste product: Dispose of remaining and non-recyclable solutions to a licensed company. Contact a professional agency with a waste disposal license to handle this substance. Burn contaminated packaging in a chemical incinerator with post-combustion and washing functions. Contaminated packaging: Dispose of as unutilized product.

First Aid / Accidental Release

  • Do not give anything to an unconscious person. Rinse mouth with water. Consult a physician.
  • If inhaled, move the patient to fresh air. If breathing stops, perform artificial respiration. Consult a physician.
  • Rinse with plenty of water for at least 15 minutes and consult a physician.
  • Wash with soap and plenty of water. Consult a physician.
  • Do not generate dust when collecting and disposing. Sweep and shovel up. Place in a suitable closed container for disposal.
  • Use personal protective equipment and emergency procedures. Avoid dust generation. Avoid inhaling vapors, mists or gases. Ensure adequate ventilation. Evacuate personnel to a safe area. Avoid inhaling dust. For personal protection, see
  • Do not allow the product to enter drains.
  • Waste product: Dispose of remaining and non-recyclable solutions to a licensed company. Contact a professional agency with a waste disposal license to handle this substance. Burn contaminated packaging in a chemical incinerator with post-combustion and washing functions. Contaminated packaging: Dispose of as unutilized product.

Firefighting / Stability

  • If necessary, wear a self-contained breathing apparatus for firefighting.
  • Reactivity and stability

Physical and Chemical Reference

Physical property reference values are not available in the current MolGraph catalog record.

Transport / Shipment Review

Shipment review

Shipment details require review before fulfillment.

Transport classification must be confirmed using supplier SDS and shipment documentation before dispatch.

  • Transport classification must be confirmed using supplier SDS and shipment documentation before dispatch.

Need supplier documentation?

Request through MolGraph:

  • Supplier-issued SDS
  • COA
  • Purity and pack size confirmation
  • Availability and lead time review
  • Shipment documentation review

Catalog-Specific Reference Cues

  • 4-(tert-Butyldimethylsilyloxymethyl)phenylboronic acid (CAS 162356-89-0) is listed in the Advanced Chemicals portfolio, with molecular formula C13H23BO3Si and molecular weight 266.22 g/mol.
  • Intended for research building-block and synthetic chemistry workflows; structure-derived tags include boronic-acid-related structure.

Related catalog entries

Related public CAS links are not available for this reference page.

MolGraph Preliminary Safety Reference - Not a supplier-issued SDS. This preliminary safety reference is generated from structured MolGraph catalog fields and public reference-style data. It is not a supplier-issued Safety Data Sheet and should not be used as a substitute for supplier-issued documentation, workplace safety review, transport classification, or regulatory compliance decisions. For supplier SDS or COA, submit a documentation request through MolGraph.