MolGraph
CompoundsDocumentationComplianceAbout
MolGraph

Research chemical sourcing and molecular building block RFQ workflows.

MolGraph is operated by Tessorix Inc.

support@molgraph.com

Products are intended for laboratory research use only and are not for human or veterinary use.

Compounds

  • Compound catalog
  • In-stock with prices
  • Research applications
  • Catalog data snapshot
  • Patent compound sourcing
  • Request Quote

Categories

  • Protected amines
  • Boronic acids
  • Fluorinated building blocks
  • Heterocycles
  • Pharmaceutical intermediates
  • Custom synthesis

Company

  • About
  • Contact

Documentation

  • Quality Documentation
  • SDS Disclaimer

Compliance

  • Compliance

Legal

  • Returns & Refunds
  • Terms
  • Privacy

Copyright © 2026 MolGraph. All Rights Reserved.

Home/Compounds/CAS 1818-71-9/Safety Reference
CAS 1818-71-9Preliminary Safety ReferenceNot a supplier-issued SDSSupplier SDS by request

CAS 1818-71-9 Safety Reference and Supplier SDS Request

Isoguanosine

Back to CAS detail

Preliminary reference disclaimer

This preliminary safety reference is generated from structured MolGraph catalog fields and public reference-style data. It is not a supplier-issued Safety Data Sheet and should not be used as a substitute for supplier-issued documentation, workplace safety review, transport classification, or regulatory compliance decisions. For supplier SDS or COA, submit a documentation request through MolGraph.

Documentation status

Preliminary safety reference

Available

Supplier-issued SDS

Available by request

COA

Available by RFQ / lot confirmation

Transport classification

Requires shipment review

Identity

CAS Number

1818-71-9

Chemical name

Isoguanosine

Molecular formula

C10H13N5O5

Molecular weight

283.24 g/mol

Synonyms

Crotonoside; 2-Hydroxyadenosine; Isoguanine riboside; Adenosine, 1,2-dihydro-2-oxo-; 1,2-Dihydro-2-oxoadenosine; 6-amino-9-[(2R,3R,4S,5R)-3,4-dihydroxy-5-(hydroxymethyl)tetrahydrofuran-2-yl]-1H-purin-2-one; 6-amino-9-((2R,3R,4S,5R)-3,4-dihydroxy-5-(hydroxymethyl)oxolan-2-yl)-1H-purin-2-one; 6-amino-9-((2R,3R,4S,5R)-3,4-dihydroxy-5-(hydroxymethyl)tetrahydrofuran-2-yl)-1H-purin-2-one; Crotonosid; Adenosine, 2,3-dihydro-2-oxo-; (2R,3R,4S,5R)-2-(6-Amino-2-hydroxy-9H-purin-9-yl)-5-(hydroxymethyl)tetrahydrofuran-3,4-diol; 6-azanyl-9-[(2R,3R,4S,5R)-5-(hydroxymethyl)-3,4-bis(oxidanyl)oxolan-2-yl]-1H-purin-2-one

InChIKey

MIKUYHXYGGJMLM-UUOKFMHZSA-N

PubChem CID

65085

Hazard / GHS Reference

Signal word

Warning

Catalog reference cue; confirm supplier documentation before use.

Hazard statements

H302, H315, H319

Catalog reference cue; confirm supplier documentation before use.

Handling & PPE

  • Keep container tightly closed and dry. Store in a well-ventilated place. Recommended storage conditions: keep away from light, inert gas, 2-8°C
  • If exposed to a harmful environment, use a P95 (US) or P1 (EU UK 143) particulate respirator. For higher level of protection, use an OV/AG/P99 (US) or ABEK-P2 (EU UK 143) gas filter. Respirators must be tested and approved by government standards such as NIOSH (US) or CEN (EU).
  • Dispose of remaining and non-recyclable solutions to a licensed company. Contact a professional institution with a waste disposal license to handle this substance. Burn in a chemical incinerator with post-combustion and washing capabilities if soluble or mixed with flammable solvents. Burn contaminated packaging. Contaminated packaging is to be disposed of as unused product.

First Aid / Accidental Release

  • Do not give anything to an unconscious person. Rinse mouth with water. Consult a physician.
  • If inhaled, move the person to fresh air. If breathing stops, perform artificial respiration. Consult a physician.
  • Rinse with plenty of water for at least 15 minutes and consult a physician.
  • Wash with soap and plenty of water. Consult a physician.
  • Do not generate dust when collecting and disposing.
  • Use personal protective equipment and emergency procedures. Avoid dust generation. Avoid inhalation of vapors, mists or gases. Ensure adequate ventilation. Evacuate personnel to a safe area. Avoid inhalation of dust. See
  • Do not allow the product to enter drains.
  • Dispose of remaining and non-recyclable solutions to a licensed company. Contact a professional institution with a waste disposal license to handle this substance. Burn in a chemical incinerator with post-combustion and washing capabilities if soluble or mixed with flammable solvents. Burn contaminated packaging. Contaminated packaging is to be disposed of as unused product.

Firefighting / Stability

  • If necessary, wear a self-contained breathing apparatus during firefighting.
  • Stability and reactivity
  • Carbon monoxide, carbon dioxide, nitrogen oxides

Physical and Chemical Reference

XLogP

-3

Catalog reference value; verify against supplier SDS before use.

Transport / Shipment Review

Shipment review

Shipment details require review before fulfillment.

Transport classification must be confirmed using supplier SDS and shipment documentation before dispatch.

  • Transport classification must be confirmed using supplier SDS and shipment documentation before dispatch.

Need supplier documentation?

Request through MolGraph:

  • Supplier-issued SDS
  • COA
  • Purity and pack size confirmation
  • Availability and lead time review
  • Shipment documentation review

Catalog-Specific Reference Cues

  • Isoguanosine (CAS 1818-71-9) is listed in the Advanced Chemicals portfolio, with molecular formula C10H13N5O5 and molecular weight 283.24 g/mol.
  • Intended for research building-block and synthetic chemistry workflows; structure-derived tags include nitrogen-containing heterocycle.

Related catalog entries

Related public CAS links are not available for this reference page.

MolGraph Preliminary Safety Reference - Not a supplier-issued SDS. This preliminary safety reference is generated from structured MolGraph catalog fields and public reference-style data. It is not a supplier-issued Safety Data Sheet and should not be used as a substitute for supplier-issued documentation, workplace safety review, transport classification, or regulatory compliance decisions. For supplier SDS or COA, submit a documentation request through MolGraph.